Home > Product > Outdoor high voltage disconnector > GW9-12 series Outdoor high voltage Disconnecting

GW9-12 series Outdoor high voltage Disconnecting

Intro:GW9 -12series Outdoor high voltage Disconnecting switch, also called Knife switch, is applied to rated voltage 12kV of 3phase AC 50HZ outdoor power system. Under the no load conditions it can switch on and off circuit to ensure when circuit maintenance it has obvious cut-off point. The isolating switch is the vertical open design of double knife switch. The contact uses the way of crimping of double pull-out piece spring. It assures the stability of switch electrical contact and the reliability of switching. The switch consists of base, post insulator conducting parts, insurance hook and etc. Each phase has a knife switch, and insulation hook rod can be used to open and close divide-shut brake. The knife switch itself has a self-locking unit. The product conforms to IEC129, IEC694,GB1985-89.
Product Description

Description

       GW9 -12 series Outdoor high voltage Disconnecting switch, also called Knife switch, is applied to rated voltage 12kV of  3phase AC 50HZ outdoor power system. Under the no load conditions it can switch on and off circuit to ensure when circuit maintenance it has obvious cut-off point.

       The isolating switch is the vertical open design of double knife switch. The contact uses the way of crimping of double pull-out piece spring. It assures the stability of switch electrical contact and the reliability of switching.

       The  switch consists of base, post insulator conducting parts, insurance hook and  etc. Each phase has a knife switch, and insulation  hook rod can be used to open and close divide-shut brake. The knife switch  itself has a self-locking unit. The product conforms to IEC129,  IEC694,GB1985-89.

Environment  condition
 - Ambient temperature: max +40°C min -25°C
 - Altitude: ≤1000m
 - Wind pressure: ≤700Pa (equals to wind speed 34m/s)
 - Air contamination degree: Ⅲ  degree

- Earthquake intensity: ≤8 degree
 - No corrosive or flammable gas, no frequent violent vibration

Technical  Data

1Rated Voltage (kV)101524
21min power frequency withstand voltage (Effective value) kVTo Ground425565
Between Fracture486579
3Lightning Impulse withstand voltage (Peak value) kVTo Ground

75

105125
Between Fracture85120145
4Mechanical life (Times)2000
5Rated Current (A)2004006301250400630
6Rated short time withstand current (kA/4s)6.312.52031.51620
7Rated peak withstand current (kA)1631.550804050
9Creepage distance (mm)300380

Outline & Mounting Dimensions 

3.jpg


3-1.jpg

PDF Material